Uretyco
Make it now
Liquid Silicone Rubber (LSR)

Liquid Silicone Rubber (LSR)

Elastomers
SiliconeLSRMedicalFood-Safe

Liquid silicone rubber (LSR) reference: typical properties, LSR injection molding and prototype silicone routes, design rules, food-contact and medical grades, cost drivers, and comparison with HCR, RTV, TPU and cast PU.

Liquid silicone rubber (LSR) is a two-component, platinum-catalysed (addition-cure) silicone. The low-viscosity components are mixed 1:1, injected cold into a heated mold and cured in seconds, giving highly repeatable elastomer parts. Silicone keeps its elasticity over a wide temperature range, resists ozone, UV and weathering, and is inert enough to be offered in food-contact and medical grades.

Choose LSR for flexible parts in volume: seals, gaskets, O-rings, membranes, valves, keypads and wearable or baby-care parts, especially where heat, outdoor exposure, sterilization or skin and food contact matter. For prototypes and low volumes, RTV-cast or compression-molded silicone avoids the cost of an LSR injection tool.

Mechanical and physical properties

PropertyTypical valueNotes
HardnessShore 10–80AMost parts use 30–70A; specify the target value and tolerance, commonly ±5 points.
Tensile strength≈ 6–11 MPaLower than polyurethane or TPU elastomers.
Elongation at break≈ 200–700%Softer grades stretch more.
Tear strength≈ 20–50 kN/mASTM D624 die B; high-tear grades for thin membranes.
Compression set≈ 10–30%22 h at 175 °C, post-cured; lower is better for seals.
Density≈ 1.10–1.20 g/cm³Rises with hardness and filler content.
Service temperature≈ −50 to +200 °CSpecial grades extend the range; long exposure near the upper limit hardens the rubber.
Linear shrinkage≈ 2–4%High because the mold runs hot; depends on grade, geometry and post-cure.
Dielectric strength≈ 20–25 kV/mmGood electrical insulator.
Typical values, not design allowables

Typical datasheet values for standard LSR grades after post-cure; actual values depend on the grade, hardness, part geometry and cure. Design seals with the specific grade's data and test them in the real medium and temperature.

Molding LSR

LSR runs differently from thermoplastics: the material is cold and liquid, the mold is hot, and the very low viscosity fills thin sections but also any gap in the tool. Uretyco's silicone-molding guidance, plus common LSR practice:

  • Hardness and tear targets: silicone stiffness spans an enormous range, so specify Shore hardness and tear strength, with tolerances, on the drawing.
  • Radii and demolding: avoid sharp internal corners; generous radii reduce tearing during demolding. LSR's elasticity allows undercuts and little or no draft that would lock a thermoplastic part.
  • Gate vestiges and flash: plan where gate marks and parting lines fall and map cosmetic surfaces relative to the tool splits. LSR flashes into gaps of only a few micrometres, so shut-offs on sealing faces matter.
  • Shrinkage: validate shrink separately from plastics; silicone behaves unlike thermoplastic melts and shrinks more.
  • Walls: LSR fills thin membranes and keypad webs well and tolerates wall changes better than thermoplastics, but thick sections lengthen cure time.
  • Overmolding: self-adhesive grades bond to selected thermoplastics or metals in two-shot or insert molding; adhesion must be validated.
  • Post-cure: many food-contact and medical applications require post-curing in an oven to remove volatiles and improve compression set; state it on the drawing.

Prototype and low-volume silicone

Before an LSR tool is justified, silicone parts can be RTV-cast in soft tools or compression-molded, a route commonly used for gaskets. Uretyco's guide sums it up: LSR suits higher volumes and tighter repeats, RTV suits prototyping and low volumes. Properties, surface and repeatability differ from LSR, so validate critical seals in the production grade before release.

Tolerances and surface

Once the tool is right, LSR parts repeat closely. Absolute tolerances depend on shrinkage, part size and hardness and are confirmed in the quote and the order. Soft parts also deform under the measuring force, so define how critical dimensions are measured. The surface copies the tool: polished for clear or glossy parts, textured or blasted to reduce tackiness and hide flow marks.

Finishing and secondary operations

LSR parts usually ship as molded. Typical secondary steps:

OperationPurposeNotes
Deflashing and trimmingRemove flash and gate vestigesManual or cryogenic; minimized by good tool shut-offs.
Post-curingFewer volatiles, better compression setOften required for food-contact and medical grades; adds oven time.
Surface coatingLower tack and frictionHelps assembly and the feel of soft parts.
Printing and markingLogos, legendsNeeds silicone-specific inks; adhesion is harder than on plastics.
PigmentationColorNatural LSR is translucent; colors are added as masterbatch.
Specify the grade, not just 'silicone'

Food-contact and medical suitability belongs to a specific grade and its processing, including post-cure, not to silicone in general. Name the required standard or approval in the order and request the supplier's declaration or certificate at quote time.

Cost and lead-time drivers

LSR has a low cost per part at volume but needs a demanding tool.

  • Tooling: LSR molds need precise shut-offs, venting and heating to control flash; cavity count and automation set the investment.
  • Prototype path: RTV casting or compression molding avoids the LSR tool for early quantities. Uretyco compares silicone routes and injection molding based on quantity, tolerance and cosmetic goals.
  • Material and grade: LSR costs more per kilogram than commodity thermoplastics; medical, food-contact, optical and self-adhesive grades cost more again.
  • Secondary operations: deflashing, post-curing and coating add cost and lead time.
  • Documents: inspection reports, material certificates and first-article approval are opt-in; request them at quote time.

LSR vs. common alternatives

Material and routeTemperature rangeTear and abrasionFood or medical gradesTooling and volume
LSR (injection)≈ −50 to +200 °CModerateYes, grade-specificHigh tooling cost; high volumes
HCR silicone (compression)SimilarModerate to goodYes, grade-specificLower tooling cost; low to medium volumes
RTV-cast siliconeSimilarLowerLimitedLowest tooling cost; prototypes
TPU 95ANarrower; upper limit ≈ 80–100 °CVery goodSome gradesInjection molding or 3D printing
Cast polyurethane elastomerNarrowerGoodRarelyLow tooling cost; up to about 200 parts

Silicone's weak points are tear and abrasion resistance and swelling in oils and fuels. Uretyco's silicone guide notes that silicone can sometimes replace TPU for temperature or chemical resistance, but its mechanical damping differs; where abrasion or tear loads dominate, TPU or polyurethane is usually better, and fluorosilicone is used for fuel contact.

When not to choose LSR

Common mismatches

Immersion in fuels or mineral oils: use fluorosilicone or a fluoroelastomer. Abrasive wear or high tear loads: use polyurethane or TPU. Very low quantities where an LSR tool will not pay back: use RTV or compression molding. Rigid or load-bearing parts. Gas-tight membranes: silicone is highly permeable to gases.

Typical applications

  • Seals, gaskets and O-rings.
  • Medical masks, valves and device seals.
  • Baby-care and kitchen products.
  • Keypads, wearable straps and soft-touch covers.
  • Connector seals and automotive boots.
  • LED lenses and light guides in optical grades.

Specifying LSR on Uretyco

  1. 1
    Specify grade and hardness

    Shore A value with tolerance, color, and any food-contact, medical or flame-retardant requirement by name.

  2. 2
    Upload STEP plus a drawing

    Show sealing faces, allowed parting-line and gate areas, critical dimensions with the measurement method, and post-cure requirements.

  3. 3
    Plan prototypes and first articles

    Validate with RTV or prototype-tool parts, then request first-article approval and documents at quote time.

FAQ

LSR or RTV silicone?

LSR suits higher volumes and tighter repeats; RTV suits prototyping and low volumes. A common path is RTV or compression-molded parts for validation, then an LSR tool once the design and quantities are stable.

Is LSR food-safe and biocompatible?

Specific grades are formulated and tested for food contact (for example FDA 21 CFR 177.2600 or BfR Recommendation XV) or for biocompatibility (ISO 10993 or USP Class VI testing), usually combined with post-curing. Compliance belongs to the grade and the finished part, and for medical devices the device manufacturer remains responsible for validation.

Can silicone replace TPU?

Sometimes, mainly for temperature or chemical resistance, but mechanical damping, tear and abrasion behave differently. Silicone stays flexible from deep cold to about 200 °C; TPU is tougher against wear and tearing at moderate temperatures.

Can LSR parts be clear or colored?

Yes. Natural LSR is translucent, optical grades are highly transparent, and pigments give solid colors matched to RAL, Pantone or a sample. Expect small shade differences between batches and state color tolerance for visible parts.

Related materials

Was this page helpful?

Can't find what you need? Contact our team for expert assistance with your manufacturing project.

Contact our team